TDTN-10000–63000/110-U1 (UHL1) type three-winding power transformers with on-load tap changer (OLTC)

product
Power transformer, three-phase, three-winding, with natural oil circulation and forced air cooling, equipped with on-load tap changer (OLTC). OLTC regulation range (HV side): ±9 × 1.78%. Off-circuit tap changer (DETC) provided. Automatic control is provided by a controller supplied together with the transformer. TDTN-type transformers ensure reliable power supply throughout their service life.
Get the cost
Application sent

By clicking the “Calculate” button, you consent to the processing of personal data.

Description

Power transformer, three-phase, three-winding, with natural oil circulation and forced air cooling, equipped with on-load tap changer (OLTC). OLTC regulation range (HV side): ±9 × 1.78%. Off-circuit tap changer (DETC) provided. Automatic control is provided by a controller supplied together with the transformer. TDTN-type transformers ensure reliable power supply throughout their service life.

Power range

Rated power range: 10000–63000 kVA
Climatic category: U1 / UHL1

Transformer symbols

Т – Three-phase transformer
D – Natural oil circulation and forced air cooling
Т – Three-winding
– On-load voltage regulation (OLTC)
Х – Rated power, kVA
110 – HV voltage class, kV
U1 or UHL1 – Climatic design and installation category in accordance with  GOST 15150

Characteristic

Technical characteristics DTN-10000–63000/110-U1 (UHL1) type transformers
Parameter
Value
Transformer type
TDTN
Rated power, kVA
10000
16000
25000
40000
63000
Rated voltage, HV winding, kV
115
Rated voltage, MV winding, kV
38,5 (35)
Rated voltage, LV winding, kV
6,6; 11,0
Winding connection diagramand vector group
Yn/Yn/D-0-11, Yn/D/D-11-11
No-load losses, kW
17
21
28,5
39
53
Short-circuit losses, kW 76 100 140 200 290
Short-circuit voltage, HV-MV, %
10,5
10,5
10,5
10,5
10,5
Short-circuit voltage,  HV-LV, % 17,5 17,5 17,5 17,5 18
Short-circuit voltage,  MV-LV, % 6,5 6,5 6,5 6,5 7
No-load current, % 0,6 0,5 0,4 0,3 0,2
Dimensions, mm
L (length) 5255 6250 6280 6000 6475
B (width) 3360 3940 4120 4440 4200
H (height) 4994 5191 5625 5330 5900
Oil weight, kg 13420 13800 17050 16450 20410
Transport weight, kg 34489 40985 54100 60780 81965
Total weight, kg 39559 46800 61930 70180 95120

Dimensional drawings

print
Power transformer, three-phase, three-winding, with natural oil circulation and forced air cooling, equipped with on-load tap changer (OLTC). OLTC regulation range (HV side): ±9 × 1.78%. Off-circuit tap changer (DETC) provided. Automatic control is provided by a controller supplied together with the transformer. TDTN-type transformers ensure reliable power supply throughout their service life.
Get the cost
Please fill in all fields with *
Application sent

By clicking the “Calculate” button, you consent to the processing of personal data.

team
Tusov Artem Aleksandrovich
Deputy Director for Marketing and Sales

Can't decide?

Consultation and equipment selection over the phone

Your name

Phone

Your application has been submitted for development
[10]
By clicking the “Request a call” button, you consent to the processing of personal data.