Quality in every coil. Reliability in every delivery.
ico
ico ico En ico
Color scheme:
A A A
Font size:
A A A A A
Copyright © 2026 AO "Чирчикский Трансформаторный Завод"
ico
Color scheme:
A A A
Font size:
A A A A A
sound Screen reader
The website features screen reader. To listen to the text, simply highlight it with the mouse and click on the appearing icon.

TRDN-25000–63000/110-U1 (UHL1) type two-winding power transformers with split LV winding and on-load tap changer (OLTC)

product
Power transformer, three-phase, two-winding, with split LV winding, natural oil circulation and forced air cooling, equipped with on-load tap changer (OLTC). Automatic control is provided by a controller supplied together with the transformer. TRDN-type transformers ensure reliable power supply throughout their service life.
Get the cost
Application sent

By clicking the “Calculate” button, you consent to the processing of personal data.

Description

Power transformer, three-phase, two-winding, with split LV winding, natural oil circulation and forced air cooling, equipped with on-load tap changer (OLTC). Automatic control is provided by a controller supplied together with the transformer. TRDN-type transformers ensure reliable power supply throughout their service life.

Power range

Rated power range: 25000÷63000 kVA
HV winding rated voltage:  115 kV
LV winding rated voltage: 6.6–6.6 (11–11) kV
Climatic category: U 1 / UHL1

Transformer symbols

Т  – Three-phase transformer
R  – Split LV winding
D  – Natural oil circulation and forced air cooling
N  – On-load tap changer (OLTC)
Х  – Rated power, kVA
110  – HV voltage class, kV
U1  or  UHL1  – Climatic category and installation type in accordance with GOST 15150

Characteristic

Main Technical Characteristics TRDN-25000–63,000/110-U1 (UHL1) type transformers
Parameter
Value
Transformer type
TRDN-25000/110
TRDN-40000/110
TRDN-63000/110
Rated power, kVA
25000
40000
63000
HV winding rated voltage , kV
115
115
115
LV winding rated voltage , kV
6,3-6,3; 10,5-10,5
6,3-6,3; 10,5-10,5
6,3-6,3; 10,5-10,5
Winding connection diagram and vector group
Yn/D-D-11-11
Yn/D-D-11-11
Yn/D-D-11-11
No-load losses, kW
25
34
50
Short-circuit losses, kW
120
170
245
Short-circuit voltage HV–LV, %
10,5
10,5
10,5
Short-circuit voltage HV–LV1 (LV2), % 20 20 20
Short-circuit voltage LV1–LV2, not less than, % 30 30 30
No-load current, % 0,4 0,55 0,2

Overall and Mounting Dimensions

Overall dimensions of TRDN-25000–63000/110-U1 (UHL1) type transformers
Transformer type
Dimensions, mm
Weight, kg
L B H Oil weight
Shipping weight
Total weight
TRDN-25000/110
5900
4080
5400
15000
43705
50130
TRDN-40000/110
5980
4655
5215
12200
48220
57900
TRDN-63000/110
6080
4500
5520
18625
70040
79725

Dimensional drawings

print
Power transformer, three-phase, two-winding, with split LV winding, natural oil circulation and forced air cooling, equipped with on-load tap changer (OLTC). Automatic control is provided by a controller supplied together with the transformer. TRDN-type transformers ensure reliable power supply throughout their service life.
Get the cost
Please fill in all fields with *
Application sent

By clicking the “Calculate” button, you consent to the processing of personal data.

team
Tusov Artem Aleksandrovich
Deputy Director for Marketing and Sales

Can't decide?

Consultation and equipment selection over the phone

Your name

Phone

Your application has been submitted for development
[10]
By clicking the “Request a call” button, you consent to the processing of personal data.