O – Single-phase
NDC – Forced air and oil circulation with directed oil flow
E –
Designed for electric rolling stock applications
4350 – Rated power, kVA
25 – Line winding nominal voltage, kV
P – Suspended design
U2 –
Climatic category and installation type in accordance with GOST 15150
|
Traction transformers — ONDCE-4350/25P-U2
|
|
|
Parameter
|
Value
|
|
Transformer type
|
ОНДЦЭ-4350/25 П-У2 |
|
Rated power of line winding, kV∙A
|
4345 |
|
Rated voltage of line winding, kV
|
25 |
|
Supply frequency, Hz
|
50 |
| Rated voltage of traction winding terminals, V | а₁-х₁ а₂-х₂ 1260 |
| а₁-2, 2-х₁, а₂-4, 4-х₂ 630 |
|
| а₁-1, 1-2, а₂-3, 3-4 315 |
|
| Rated power of auxiliary winding, kV∙A | 205 |
| Rated voltage of auxiliary winding terminals, V | а₄-х₄ 401 |
| а₄-6 229 | |
| Rated power of excitation winding, kVA | 112 |
|
Rated voltage of excitation winding terminals, V
|
а₃-5 86 |
| 5-х₃ 86 | |
| Rated power of heating winding, kVA | - |
| Rated voltage of heating winding terminals, V | - |
| Total transformer losses, kW | 60,5 |
| Winding connection diagramand vector group | 1/1-1-1-1-0-0-0-0 |
| Oil weight, kg | 1450 |
| Total weight, kg | 7500 |
By clicking the “Calculate” button, you consent to the processing of personal data.
Your name
Phone